Timber Beam Bearing Capacity Calculator

Design bearing capacity perpendicular to grain in accordance with AS 1720.1.

AS 1720.1 • Clause 3.2.6.1 • Clause 2.4 • Appendix H
1. Timber & Bearing Property
AS 1720.1 Appendix H — Table H2.2.
Strength group is selected from the applicable species classification.
MGP bearing properties are based on SD6 or better; A17 on SD4 or better.
Bearing perpendicular to grain.
Selected SD4 → f′p = 17 MPa.
2. Structural Application Category & Capacity Factor φ
Select the Structural Application Category applicable to the consequence of failure and structural function of the member. Confirm the project-specific category from AS 1720.1.
3. Bearing Geometry
Measured parallel to grain.
4. Duration of Load Factor k₁
5. Moisture / Seasoning Factor k₄
6. Temperature Factor k₆
7. Bearing Length & Position Factor k₇
End bearing → k₇ = 1.00.
8. Design Bearing Action
Enter the strength-limit-state reaction at the bearing being checked.
Normally use 1 when checking one support location.
Nd,p = φ × k₁ × k₄ × k₆ × k₇ × f′p × Ap
Bearing perpendicular to grain
Design Results
Bearing Area Aₚ —
Design Bearing Stress —
Design Capacity Nd,p —
Utilisation —
Enter the design information and calculate.
Calculation Breakdown
—
Parameter Value Description
φ — Capacity factor
k₁ — Duration of load
k₄ — Moisture / seasoning
k₆ — Temperature
k₇ — Bearing length and position
f′p — Characteristic bearing strength
JS