AS/NZS 1170.2 Site Wind Speed Calculator
Calculate site wind speed Vsit,β from regional wind speed
and site exposure multipliers
Vsit,β =
VR × Md ×
Mz,cat × Ms × Mt
1 — Regional Wind Speed, VR
AS/NZS 1170.2:2011 — Clause 3.2
Enter the regional gust wind speed determined
from Section 3.
Required for determining Md.
2 — Climate Change Multiplier
Edition check
Climate multiplier used in attached 2011 basis
Mc = 1.000
Important:
The attached AS/NZS 1170.2:2011 edition does not include
a climate-change multiplier in Equation 2.2.
Therefore this calculator does not multiply the 2011
site-wind-speed equation by a climate factor.
AS/NZS 1170.2:2021 introduced a climate-change multiplier.
3 — Wind Direction Multiplier, Md
Clause 3.3 — Table 3.2
Wind direction multiplier
Md = 1.000
Md is determined from the selected wind region,
wind direction and structural application.
4 — Terrain / Height Multiplier,
Mz,cat
Clauses 4.2.1 & 4.2.2 — Table 4.1
Generally the average roof height is used,
subject to the applicable structural provisions.
Terrain / height multiplier
Mz,cat = 0.830
Table 4.1 values are linearly interpolated for
intermediate heights and intermediate terrain
categories TC1.5 and TC2.5.
5 — Shielding Multiplier,
Ms
Clause 4.3 — Table 4.3
Only qualifying upwind buildings within the applicable
shielding sector should be counted. Trees and vegetation
are not used as shielding under the attached 2011 Standard.
Shielding multiplier
Ms = 1.000
Shielding is currently ignored, therefore
Ms = 1.0.
6 — Topographic Multiplier,
Mt
Clause 4.4
Topographic multiplier
Mt = 1.000
Flat or insignificant topography selected.
7 — Site Wind Speed,
Vsit,β
AS/NZS 1170.2:2011 — Clause 2.2
Md
1.000
Mz,cat
0.830
Ms
1.000
Mt
1.000
VR
45.0
SITE WIND SPEED
Vsit,β =
—
m/s
AS/NZS 1170.2:2011 — Equation 2.2
Enter the project parameters and select
“Calculate Site Wind Speed”.
This engineering tool assists with calculation only.
Terrain, shielding, topography, wind region and wind direction
must be selected using engineering judgement and the complete
requirements of AS/NZS 1170.2.