AS 1720.1 Timber Beam Bending Capacity Calculator

Complete F-grade rectangular sawn timber beam design

Automatic design calculation:

Timber grade → f′b → φ → k₁ → k₄ → k₆ → k₉ → S₁ → ρb → k₁₂ → Z → Md → PASS / FAIL
1. Timber Grade and Condition
2. Structural Application Category
Category 1 = house members with limited consequence or secondary members.
Category 2 = primary structural members.
Category 3 = essential-service / post-disaster primary members.
3. Rectangular Beam Geometry
Z = bd² / 6
For an F-grade rectangular beam with d > 300 mm:
f′b,design = f′b,H2.1 (300/d)0.167
4. Duration of Load Factor k₁
For a load combination containing actions of different duration, select the effective duration associated with the shortest-duration action in the combination.
Calculated k₁ = 0.80
5. Moisture Condition Factor k₄
k₄ = 1.00
6. Temperature Factor k₆
Calculated k₆ = 1.00
The northern-region reduction applies to seasoned timber in the geographical regions specified by AS 1720.1 Clause 2.4.3.
7. Strength-Sharing Factor k₉
Number effectively fastened together in one group.
Number of discretely spaced parallel members.
Single beam → k₉ = 1.00
Important: k₉ > 1.0 is only appropriate when the members actually form a qualifying strength-sharing structural system.
8. Lateral Stability – S₁ and k₁₂
If lateral restraints occur only at the two beam ends, enter the actual distance between those restraint points.
When selecting a continuous restraint option, the designer must confirm that the restraint system satisfies the AS 1720.1 requirements for an effective continuous lateral restraint system.
9. Applied Design Bending Moment
f′b
—
φ
—
k₁
—
k₄
—
k₆
—
k₉
—
S₁
—
k₁₂
—
Design Bending Capacity Md
—
Md ≥ M*
—
10. Complete Calculation
Parameter Value Source / Calculation
Grade — User selection
f′b base — Table H2.1
f′b design — —
φ — Table 2.1
Z — Z = bd² / 6
k₁ — Duration of load
k₄ — Moisture condition
k₆ — Temperature / location
k₉ — Strength sharing
ρb — Table 3.1
S₁ — Beam restraint condition
ρbS₁ — ρb × S₁
k₁₂ — Stability factor
Combined kmod — k₁k₄k₆k₉k₁₂
Md — φk₁k₄k₆k₉k₁₂f′bZ
M* — Applied design moment
Utilization — M* / Md
Scope: This calculator is for a straight, solid rectangular F-grade sawn timber beam bending about its major axis. It is intentionally not applying the same F-grade rules to MGP, A17, LVL or glulam because those products have separate property and modification provisions in AS 1720.1.